  "category": "battery-ev",
  "version": "annex-xiii-2027.1",
  "source": "Regulation (EU) 2023/1542, Annex XIII — https://eur-lex.europa.eu/eli/reg/2023/1542/oj",
  "effectiveDate": "2027-02-18",
  "attributes": [
    {
      "id": "manufacturerName",
      "label": "Manufacturer name",
      "type": "string",
      "required": "issuance",
      "group": "general-info",
      "accessTier": "public",
      "source": "Annex XIII, §1"
    },
    {
      "id": "manufacturerAddress",
      "label": "Manufacturer address",
      "type": "string",
      "required": "issuance",
      "group": "general-info",
      "accessTier": "public",
      "source": "Annex XIII, §1"
    },
    {
      "id": "manufacturerWebsite",
      "label": "Manufacturer website",
      "type": "uri",
      "required": false,
      "group": "general-info",
      "accessTier": "public",
      "source": "Annex XIII, §1"
    },
    {
      "id": "manufacturerEori",
      "label": "Manufacturer EORI number",
      "type": "string",
      "required": "registration",
      "group": "authority-data",
      "accessTier": "competent-authority",
      "source": "Annex XIII, §1"
    },
    {
      "id": "batteryModel",
      "label": "Battery model",
      "type": "string",
      "required": "issuance",
      "group": "general-info",
      "accessTier": "public",
      "source": "Annex XIII, §2"
    },
    {
      "id": "batteryCategory",
      "label": "Battery category",
      "type": "enum",
      "required": "issuance",
      "group": "general-info",
      "accessTier": "public",
      "source": "Annex XIII, §2",
      "enum": [
        "EV",
        "LMT",
        "Industrial"
      ]
    },
    {
      "id": "batteryStatus",
      "label": "Battery status",
      "type": "enum",
      "required": "issuance",
      "group": "general-info",
      "accessTier": "public",
      "source": "Annex XIII, §2",
      "enum": [
        "original",
        "repurposed",
        "remanufactured",
        "reused",
        "waste"
      ]
    },
    {
      "id": "manufacturingDate",
      "label": "Manufacturing date",
      "type": "date",
      "required": "issuance",
      "group": "general-info",
      "accessTier": "public",
      "source": "Annex XIII, §2"
    },
    {
      "id": "manufacturingPlace",
      "label": "Manufacturing place",
      "type": "string",
      "required": "issuance",
      "group": "general-info",
      "accessTier": "public",
      "source": "Annex XIII, §2"
    },
    {
      "id": "ratedCapacityAh",
      "label": "Rated capacity (Ah)",
      "type": "number",
      "required": "issuance",
      "group": "capacity-energy",
      "accessTier": "public",
      "source": "Annex XIII, §3",
      "unit": "Ah"
    },
    {
      "id": "ratedCapacityKwh",
      "label": "Rated energy capacity (kWh)",
      "type": "number",
      "required": "issuance",
      "group": "capacity-energy",
      "accessTier": "public",
      "source": "Annex XIII, §3",
      "unit": "kWh"
    },
    {
      "id": "nominalVoltage",
      "label": "Nominal voltage (V)",
      "type": "number",
      "required": "issuance",
      "group": "capacity-energy",
      "accessTier": "public",
      "source": "Annex XIII, §3",
      "unit": "V"
    },
    {
      "id": "minVoltage",
      "label": "Minimum voltage (V)",
      "type": "number",
      "required": false,
      "group": "capacity-energy",
      "accessTier": "public",
      "source": "Annex XIII, §3",
      "unit": "V"
    },
    {
      "id": "maxVoltage",
      "label": "Maximum voltage (V)",
      "type": "number",
      "required": false,
      "group": "capacity-energy",
      "accessTier": "public",
      "source": "Annex XIII, §3",
      "unit": "V"
    },
    {
      "id": "originalPowerCapabilityW",
      "label": "Original power capability (W)",
      "type": "number",
      "required": false,
      "group": "capacity-energy",
      "accessTier": "public",
      "source": "Annex XIII, §3",
      "unit": "W"
    },
    {
      "id": "chemistry",
      "label": "Battery chemistry",
      "type": "string",
      "required": "issuance",
      "group": "cell-chemistry",
      "accessTier": "legitimate-interest",
      "source": "Annex XIII, §4",
      "description": "e.g. NMC811, LFP, NCA"
    },
    {
      "id": "cathodeActiveMaterials",
      "label": "Cathode active materials",
      "type": "string",
      "required": "registration",
      "group": "cell-chemistry",
      "accessTier": "legitimate-interest",
      "source": "Annex XIII, §4"
    },
    {
      "id": "anodeActiveMaterials",
      "label": "Anode active materials",
      "type": "string",
      "required": false,
      "group": "cell-chemistry",
      "accessTier": "legitimate-interest",
      "source": "Annex XIII, §4"
    },
    {
      "id": "electrolyte",
      "label": "Electrolyte composition",
      "type": "string",
      "required": false,
      "group": "cell-chemistry",
      "accessTier": "legitimate-interest",
      "source": "Annex XIII, §4"
    },
    {
      "id": "carbonFootprintKgCo2ePerKwh",
      "label": "Carbon footprint (kgCO2e/kWh)",
      "type": "number",
      "required": "registration",
      "group": "carbon-footprint",
      "accessTier": "public",
      "source": "Annex XIII, §5",
      "unit": "kgCO2e/kWh"
    },
    {
      "id": "carbonFootprintStudyUrl",
      "label": "Carbon footprint study URL",
      "type": "uri",
      "required": "registration",
      "group": "carbon-footprint",
      "accessTier": "public",
      "source": "Annex XIII, §5"
    },
    {
      "id": "carbonFootprintLifecycleStage",
      "label": "Carbon footprint per lifecycle stage",
      "type": "object",
      "required": false,
      "group": "carbon-footprint",
      "accessTier": "public",
      "source": "Annex XIII, §5"
    },
    {
      "id": "recycledContentCobaltPct",
      "label": "Recycled cobalt content (%)",
      "type": "number",
      "required": "registration",
      "group": "recycled-content-detail",
      "accessTier": "legitimate-interest",
      "source": "Annex XIII, §6",
      "unit": "%"
    },
    {
      "id": "recycledContentLithiumPct",
      "label": "Recycled lithium content (%)",
      "type": "number",
      "required": "registration",
      "group": "recycled-content-detail",
      "accessTier": "legitimate-interest",
      "source": "Annex XIII, §6",
      "unit": "%"
    },
    {
      "id": "recycledContentNickelPct",
      "label": "Recycled nickel content (%)",
      "type": "number",
      "required": "registration",
      "group": "recycled-content-detail",
      "accessTier": "legitimate-interest",
      "source": "Annex XIII, §6",
      "unit": "%"
    },
    {
      "id": "recycledContentLeadPct",
      "label": "Recycled lead content (%)",
      "type": "number",
      "required": false,
      "group": "recycled-content-detail",
      "accessTier": "legitimate-interest",
      "source": "Annex XIII, §6",
      "unit": "%"
    },
    {
      "id": "renewableContentPct",
      "label": "Renewable content (%)",
      "type": "number",
      "required": false,
      "group": "renewable-content",
      "accessTier": "public",
      "source": "Annex XIII, §7",
      "unit": "%"
    },
    {
      "id": "hazardousSubstances",
      "label": "Hazardous substances",
      "type": "array",
      "required": "registration",
      "group": "hazardous-substances",
      "accessTier": "legitimate-interest",
      "source": "Annex XIII, §8",
      "description": "Array of {substance, concentration, locationUrl}"
    },
    {
      "id": "safetyRequirementsUrl",
      "label": "Safety requirements documentation URL",
      "type": "uri",
      "required": "registration",
      "group": "safety-labels",
      "accessTier": "public",
      "source": "Annex XIII, §9"
    },
    {
      "id": "extinguishingAgents",
      "label": "Extinguishing agents",
      "type": "string",
      "required": false,
      "group": "safety-labels",
      "accessTier": "public",
      "source": "Annex XIII, §9"
    },
    {
      "id": "stateOfHealth",
      "label": "State of health (%)",
      "type": "number",
      "required": "issuance",
      "group": "state-of-health",
      "accessTier": "legitimate-interest",
      "source": "Annex XIII, §10",
      "unit": "%",
      "description": "At time of issuance: 100. Updated by repairers/operators."
    },
    {
      "id": "stateOfCharge",
      "label": "State of charge (%)",
      "type": "number",
      "required": false,
      "group": "state-of-health",
      "accessTier": "legitimate-interest",
      "source": "Annex XIII, §10",
      "unit": "%"
    },
    {
      "id": "capacityFade",
      "label": "Capacity fade (%)",
      "type": "number",
      "required": false,
      "group": "state-of-health",
      "accessTier": "legitimate-interest",
      "source": "Annex XIII, §10",
      "unit": "%"
    },
    {
      "id": "powerFade",
      "label": "Power fade (%)",
      "type": "number",
      "required": false,
      "group": "state-of-health",
      "accessTier": "legitimate-interest",
      "source": "Annex XIII, §10",
      "unit": "%"
    },
    {
      "id": "internalResistanceIncrease",
      "label": "Internal resistance increase (%)",
      "type": "number",
      "required": false,
      "group": "internal-resistance",
      "accessTier": "legitimate-interest",
      "source": "Annex XIII, §10",
      "unit": "%"
    },
    {
      "id": "cycleLifeReferenceTest",
      "label": "Expected cycle life (reference test)",
      "type": "number",
      "required": "registration",
      "group": "electrochemical",
      "accessTier": "legitimate-interest",
      "source": "Annex XIII, §11",
      "unit": "cycles"
    },
    {
      "id": "capacityThresholdExhaustion",
      "label": "Capacity threshold exhaustion (%)",
      "type": "number",
      "required": false,
      "group": "electrochemical",
      "accessTier": "legitimate-interest",
      "source": "Annex XIII, §11",
      "unit": "%"
    },
    {
      "id": "supplyChainDueDiligenceUrl",
      "label": "Supply chain due diligence report URL",
      "type": "uri",
      "required": "registration",
      "group": "due-diligence",
      "accessTier": "legitimate-interest",
      "source": "Annex XIII, §12"
    },
    {
      "id": "cobaltSourcingCountries",
      "label": "Cobalt sourcing countries",
      "type": "array",
      "required": "registration",
      "group": "supply-chain",
      "accessTier": "legitimate-interest",
      "source": "Annex XIII, §12",
      "description": "ISO 3166-1 alpha-2 codes"
    },
    {
      "id": "lithiumSourcingCountries",
      "label": "Lithium sourcing countries",
      "type": "array",
      "required": "registration",
      "group": "supply-chain",
      "accessTier": "legitimate-interest",
      "source": "Annex XIII, §12",
      "description": "ISO 3166-1 alpha-2 codes"
    },
    {
      "id": "nickelSourcingCountries",
      "label": "Nickel sourcing countries",
      "type": "array",
      "required": false,
      "group": "supply-chain",
      "accessTier": "legitimate-interest",
      "source": "Annex XIII, §12",
      "description": "ISO 3166-1 alpha-2 codes"
    },
    {
      "id": "endOfLifeUrl",
      "label": "End-of-life information URL",
      "type": "uri",
      "required": "registration",
      "group": "circularity",
      "accessTier": "public",
      "source": "Annex XIII, §13"
    },
    {
      "id": "dismantlingInstructionsUrl",
      "label": "Dismantling instructions URL",
      "type": "uri",
      "required": "registration",
      "group": "circularity",
      "accessTier": "public",
      "source": "Annex XIII, §13"
    },
    {
      "id": "separabilityDisassembly",
      "label": "Separability/disassembly information",
      "type": "string",
      "required": false,
      "group": "circularity",
      "accessTier": "public",
      "source": "Annex XIII, §13"
    },
    {
      "id": "declarationOfConformityUrl",
      "label": "Declaration of conformity URL",
      "type": "uri",
      "required": "registration",
      "group": "declarations",
      "accessTier": "competent-authority",
      "source": "Annex XIII, §14"
    },
    {
      "id": "testReportsUrl",
      "label": "Test reports URL",
      "type": "uri",
      "required": false,
      "group": "test-reports",
      "accessTier": "competent-authority",
      "source": "Annex XIII, §14"
    },
    {
      "id": "euDeclarationOfConformity",
      "label": "EU declaration of conformity reference",
      "type": "string",
      "required": "registration",
      "group": "declarations",
      "accessTier": "competent-authority",
      "source": "Annex XIII, §14"
    }
  ]
}